Return to index: [Subject] [Thread] [Date] [Author]
AREMA Serviceability Requirements
[Subject Prev][Subject Next][Thread Prev][Thread Next]- To: seaint(--nospam--at)seaint.org
- Subject: AREMA Serviceability Requirements
- From: Michael Hemstad <mlhemstad(--nospam--at)yahoo.com>
- Date: Mon, 14 Apr 2003 14:11:57 -0700 (PDT)
Pedro Munoz wrote: "Can someone familiar with the latest AREMA 2002 Serviceability Requirements for Concrete Structures comment on the practicality of the Fatigue and Distribution of Flexural Reinforcement equations. Does anyone know if AREMA have any kind of guidelines for the applicability of those two requirements, like some Examples on how to apply them to real cases ? It looks like AREAMA and ACI are not up to par with the Distribution of Flexural Requirements, AREMA still uses the Z factor. Can anyone, Please comment on this. Pedro R. Munoz, Ph.D., P.E. Senior Structural Engineer DMJM+HARRIS" Pedro, I'm not sure exactly what you're asking, but I'll take a shot at it. These sections of AREMA are identical to AASHTO (at least the 16th Edition). These two codes typically lag somewhat behind ACI in terms of incorporating the latest research. Personally, I don't feel this is all bad, but that's a much longer discussion. The current ACI section 10.6.4 was apparently derived from the older Z-cracking equation. Reading the ACI commentary, it is a somewhat more direct way to get to what you really want, which is the required bar spacing. Given the gross imprecision of any cracking calculation, I don't think it's possible to say one way is better than the other on a technical level. Both the fatigue and Z-cracking sections require the engineer to evaluate reinforcing stresses at service level. The current 10.6.4 still does, as I read it. Calculating the reinforcing stresses in a section which undergoes moment reversal is tricky, because when the reinforcing is in compression it is part of a different section modulus, so you get to make some assumptions about the new tension steel in order to calculate this. Fortunately, the calculated compression is not too sensitive to your assumption. If we don't know, we usually assume the steel to be the same on each face for this calculation. Whether either equation is "practical" depends, I suppose, on your point of view. They've both worked fairly well for a long time. They both require a lot of calculation, which sometimes tends to inspire false confidence in their accuracy or validity. If you have a specific question on how to apply it, respond and I'll take a shot at it too. I recommend caffiene be taken beforehand. If none of this answers your question, I talked to a co-worker of mine who serves on the AREMA Technical Committee which maintains Chapter 8. He suggested you forward your inquiry to Committee 8 Chairman Don Ladner @ dladner(--nospam--at)ekmail.com. Apologies to Don. HTH, Mike Hemstad, P.E. TKDA St. Paul, Minnesota __________________________________________________ Do you Yahoo!? Yahoo! Tax Center - File online, calculators, forms, and more http://tax.yahoo.com ******* ****** ******* ******** ******* ******* ******* *** * Read list FAQ at: http://www.seaint.org/list_FAQ.asp * * This email was sent to you via Structural Engineers * Association of Southern California (SEAOSC) server. To * subscribe (no fee) or UnSubscribe, please go to: * * http://www.seaint.org/sealist1.asp * * Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you * send to the list is public domain and may be re-posted * without your permission. Make sure you visit our web * site at: http://www.seaint.org ******* ****** ****** ****** ******* ****** ****** ********
- Prev by Subject: AREMA Serviceability Requirements
- Next by Subject: ASCE 7 Wind
- Previous by thread: AREMA Serviceability Requirements
- Next by thread: scholarchip
- About this archive
- Messages sorted by: [Subject][Thread][Author][Date]