Jim, The 1997 UBC gives values, but the relationship between your conditions and the Code values is ambiguous. The Code values are based on masonry prism strengths, not grout strength, and, for tension values, are dependent on edge distance. Prism strengths are typically less than grout strength. Some representative Working Stress values from Section 2107.5 for fm = 1500 psi, 4" edge distance tension capacity, Bt: = 970 lb; 3" edge distance tension capacity, Bt - 550 lb; 2" edge distance tension capacity, Bt = 240 lb; shear capacity, Bv = 1330 lb. Nels Roselund Structural Engineer South San Gabriel, CA njineer(--nospam--at)att.net ******* ****** ******* ******** ******* ******* ******* *** * Read list FAQ at: http://www.seaint.org/list_FAQ.asp * * This email was sent to you via Structural Engineers * Association of Southern California (SEAOSC) server. To * subscribe (no fee) or UnSubscribe, please go to: * * http://www.seaint.org/sealist1.asp * * Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you * send to the list is public domain and may be re-posted * without your permission. Make sure you visit our web * site at: http://www.seaint.org ******* ****** ****** ****** ******* ****** ****** ********
- Follow-Ups:
- Re: anchor Bolts vs sst16
- From: jim jensen
- Re: anchor Bolts vs sst16
- References:
- anchor Bolts vs sst16
- From: jim jensen
- anchor Bolts vs sst16
- Prev by Subject: anchor Bolts vs sst16
- Next by Subject: Re: anchor Bolts vs sst16
- Previous by thread: anchor Bolts vs sst16
- Next by thread: Re: anchor Bolts vs sst16
- About this archive
- Messages sorted by: [Subject][Thread][Author][Date]