Return to index: [Subject] [Thread] [Date] [Author]
Re: 10/lw factor....why can't we get along?
[Subject Prev][Subject Next][Thread Prev][Thread Next]- To: seaint(--nospam--at)seaint.org
- Subject: Re: 10/lw factor....why can't we get along?
- From: Scott Maxwell <smaxwell(--nospam--at)engin.umich.edu>
- Date: Mon, 23 Jun 2003 18:31:37 -0400 (EDT)
Joe, Ha! The joke is on you!! You thought that we would have something logical like one standardized code for the entire US?!? ;-) You had to know that someone would come along an change the best laid plans! It makes too much sense to have one code! On a more serious note, in theory, there should be VERY little difference between the IBC and NFPA 5000 when it comes to the structural provisions. The NFPA is supposedly adopting the reference standards with basically no modifications (at least that was their original intent). This should mean no modifications unless it goes through the appropriate standards committee (i.e. ACI 318 for concrete stuff, ASCE 7 for load stuff, etc). The IBC is getting much closer to such a way of doing things. Supposedly, they are also trying to minimize changes after one of the reference standards has been completed by the various groups and then adopted into the IBC. Thus, in theory, the IBC and NFPA structural provisions should be nearly identical. Now, the other parts of the codes might still be messy, but we just let the mechanical engineers, electrical engineers and architects worry about that!! ;-) HTH, Scott Ypsilanti, MI On Mon, 23 Jun 2003 Jnapd(--nospam--at)aol.com wrote: > Scott: > I thought the original intent was to have one code for all areas of the US . > That is why that phased out the UBC. Seems like we are heading back to > different codes for everybody again. > > Joe Venuti > Johnson & Nielsen Associates > Palm Springs, CA > > ******* ****** ******* ******** ******* ******* ******* *** * Read list FAQ at: http://www.seaint.org/list_FAQ.asp * * This email was sent to you via Structural Engineers * Association of Southern California (SEAOSC) server. To * subscribe (no fee) or UnSubscribe, please go to: * * http://www.seaint.org/sealist1.asp * * Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you * send to the list is public domain and may be re-posted * without your permission. Make sure you visit our web * site at: http://www.seaint.org ******* ****** ****** ****** ******* ****** ****** ********
- Follow-Ups:
- RE: 10/lw factor....why can't we get along?
- From: Dennis Wish
- RE: 10/lw factor....why can't we get along?
- References:
- Re: 10/lw factor....why can't we get along?
- From: Jnapd
- Re: 10/lw factor....why can't we get along?
- Prev by Subject: Re: 10/lw factor....why can't we get along?
- Next by Subject: RE: 10/lw factor....why can't we get along?
- Previous by thread: Re: 10/lw factor....why can't we get along?
- Next by thread: RE: 10/lw factor....why can't we get along?
- About this archive
- Messages sorted by: [Subject][Thread][Author][Date]